Dendritic-Cell Activation Testing | Cosmetic Labs

## What is Dendritic-Cell Activation Testing?

Assess activation markers in specified immune-cell models relevant to skin sensitisation. Surrogate cell-line assays, including h-CLAT where appropriate, assess markers such as CD86 and CD54 rather than directly establishing activation of epidermal Langerhans cells.

### Why do you need this service?
Immune-cell activation studies contribute to sensitisation assessment using the cell system and prediction criteria of the selected method. Surrogate cell lines should not be described as epidermal Langerhans cells, and results require integrated interpretation.

## Be the first company on this service page

No published company profiles are linked to Dendritic-Cell Activation Testing or its more specific services yet. Explore the service categories or add an explicitly supported capability to your company profile.

[List your company](https://cosmetic-labs.com/account/companies/new)
Definition
## Dendritic-cell activation and Langerhans-related responses
Langerhans cells are antigen-presenting cells in the epidermis. Their role in sensitization can be investigated directly in specialized models or indirectly through validated dendritic-cell activation methods. The exact cell system should be stated.

### Surrogate activation assays
For example, h-CLAT uses THP-1 cells and flow cytometry to measure CD86 and CD54 expression after exposure. Other methods use different cell systems and readouts. These are not interchangeable protocols, and THP-1 or U937 cells should not be described as cultured Langerhans cells.

Method-defined concentration selection and exposure conditions
- Marker expression relative to suitable controls
- Concurrent viability assessment
- Assay-specific prediction criteria and applicability checks

### Applications and limits
Results address a defined event in the sensitization pathway. Interpretation depends on solubility, cytotoxicity, analytical interference, and the method’s suitability for the material. Complex extracts and finished formulations may need particular scrutiny.

Activation data can contribute to an integrated sensitization assessment. One marker threshold is not applicable to every assay, and a negative result does not alone establish product safety or absence of allergy risk.

Applications
## Select the activation method
Methods addressing dendritic-cell activation are described under OECD Test Guideline 442E. For example, h-CLAT uses THP-1 cells and flow cytometry to assess CD86 and CD54. These cells are not cultured epidermal Langerhans cells, and other assays use different systems and readouts.

Apply the method-specific concentration selection, exposure, viability and prediction criteria. Solubility, cytotoxicity and analytical interference can limit interpretation, particularly for complex extracts and formulations. There is no generic marker threshold that applies to all activation assays.

### Integrate the result
Reports should identify the method, cell system, controls and applicability limits. Activation findings contribute to a broader sensitisation assessment rather than establishing overall product safety, guaranteed regulatory acceptance or absence of allergy risk.

ExplorationLearn more about Skin Sensitisation AssessmentSkin sensitization testing can use h-CLAT to measure CD54 and CD86 expression in THP-1 cells by flow cytometry after substance exposure. Explore another Skin Sensitisation Assessment page on cosmetic-labs.com.

#### [Peptide & Protein Reactivity](https://cosmetic-labs.com/services/in-vitro-testing/cosmetic-safety-testing/safety-testing/skin-sensitization/protein-binding)
Assess chemical reactivity with peptides or proteins using methods such as DPRA to investigate an early event in the skin sensitisation pathway. [Check this service](https://cosmetic-labs.com/services/in-vitro-testing/cosmetic-safety-testing/safety-testing/skin-sensitization/protein-binding)

Continue with

[Google](https://cosmetic-labs.com/?lean_auth=start&provider=google&redirect_to=https://cosmetic-labs.com/&error_return=https://cosmetic-labs.com/services/in-vitro-testing/cosmetic-safety-testing/safety-testing/skin-sensitization/langerhans)
[LinkedIn](https://cosmetic-labs.com/?lean_auth=start&provider=linkedin&redirect_to=https://cosmetic-labs.com/&error_return=https://cosmetic-labs.com/services/in-vitro-testing/cosmetic-safety-testing/safety-testing/skin-sensitization/langerhans)

What does “Verified” mean?
Verified means the claimant’s company affiliation was checked.

Something not right?Let us know if any information on this page is incorrect or if you have concerns about who manages it.

[Report an issue](https://cosmetic-labs.com/platform/contact)

© 2026 Cosmetic Labs. All rights reserved.

---

## Site identity

- Organization: Cosmetic Labs
- Description: Cosmetic Labs is a directory and a platform to meet all your cosmetic product development needs. From sourcing raw material to finding the best CRO for your needs.
- Website: https://cosmetic-labs.com

```json
[{"@type":"WebPage","name":"Dendritic-Cell Activation Testing","url":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization\/langerhans","mainEntity":{"@id":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization\/langerhans#service"},"isPartOf":{"@id":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization#webpage"},"breadcrumb":{"@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cosmetic-labs.com\/"},{"@type":"ListItem","position":2,"name":"Services","item":"https:\/\/cosmetic-labs.com\/services"},{"@type":"ListItem","position":3,"name":"Quality & Safety","item":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing"},{"@type":"ListItem","position":4,"name":"Cosmetic Safety Testing","item":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing"},{"@type":"ListItem","position":5,"name":"In Vitro & In Chemico Safety Testing","item":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing"},{"@type":"ListItem","position":6,"name":"Skin Sensitisation Assessment","item":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization"},{"@type":"ListItem","position":7,"name":"Dendritic-Cell Activation Testing","item":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization\/langerhans"}]},"inLanguage":"en-US","@id":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization\/langerhans#webpage"},{"@type":"Service","name":"Dendritic-Cell Activation Testing","url":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization\/langerhans","mainEntityOfPage":{"@id":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization\/langerhans#webpage"},"description":"Assess immune-cell activation markers relevant to skin sensitisation.","image":{"@type":"ImageObject","url":"https:\/\/cosmetic-labs.com\/wp-content\/uploads\/langerhans-service-1200x1200-1-1024x1024.webp","width":1024,"height":1024,"caption":"A blue-gloved hand lowers an orange-capped tube toward a circular instrument loader."},"@id":"https:\/\/cosmetic-labs.com\/services\/in-vitro-testing\/cosmetic-safety-testing\/safety-testing\/skin-sensitization\/langerhans#service"}]
```